Study on Green Preparation and Properties of Non-autoclaved Pipe Pile Concrete
Abstract
The effects of mineral admixture content, water reducing agent dosage, water-to-binder ratio and steaming system on the properties of concrete and the effect of cement content on the chloride ion permeability of concrete were studied. And the basic mix ratio of PHC pipe pile concrete is obtained: the cement dosage is ≥360kg/m3, the mineral admixture content is 22%, the water-binder ratio is ≤0.24, and the sanding rate is 0.36. The concrete thus prepared satisfies the working performance requirement, and the strength of 1d is 84.6 MPa under normal pressure steam curing conditions.
Keywords
Full Text:
PDFReferences
Zhang Xianzhe. Experimental study on mechanical properties of C80 pipe pile concrete [D]. Shaanxi: Xi'an University of Architecture and Technology, 2014.
LIANG Pengxing,LI Long,WEI Yiling. Discussion on the application of PHC pipe pile in strong corrosive environment[J]. Concrete and Cement Products,2009(6):27-28.
ZHANG Jian-gang, MAO Yong-lin, QIAO Min. Research on Pressureless Steaming Technology of PHC Pipe Pile Concrete[J]. Concrete and Cement Products, 2012(7): 31-33.
KLIMESCHDS, RAYA. Autoclaved cement quartz pastes: the effects on chemical and physical properties when using ground quartz with different surface areas Part II: results of accelerated carbonation [J]. Cement and Concrete Research, 1997, 27(7): 1073-1083.
KLIMESCHDS, RAYA, SLOANEB. Autoclaved cement quartz pastes: the effects on chemical and physical properties when using ground quartz with different surface areas Part I: quartz of wide particle size distribution [J]. Cement and Concrete Research, 1996, 26(9): 1399-1408.
Zhan Zhenfeng, Chen Qiaohui, Li Congbo, et al. Experimental study on steam-free tube pile concrete[J]. Concrete, 2015(11): 118-120.
Granulated blast furnace slag powder used in cement and concrete: GB/T18046-2008 [S]. Beijing: China Standard Press, 2008.
Concrete slump meter: JG/3021-1994 [S]. Beijing: China Standard Press, 1994.
Standard Test Method for Mechanical Properties of Ordinary Concrete: GB/T50081-2002 [S]. Beijing: China Building Industry Press, 2002.
Standard Test Method for Long-Term Performance and Durability of Conventional Coagulation: GB/T50082—2009[S]. Beijing: China Building Industry Press, 2009.
DOI: http://dx.doi.org/10.18686/ct.v1i1.1346
Refbacks
- There are currently no refbacks.